PC

ProtocolCore

Suggested Protocols

Exploratory MVP
All protocol fields

Gene Delivery / Transfection

Source-bound Gene Delivery / Transfection starter protocols

Use one common identity, execution, outcome, and handoff contract plus two exact source profiles. Cell, payload, reagent, vessel, and scale values never cross profiles; CRISPR and Protein Production receive typed receipts only.

Editable starter protocols

3 source-bound starters

What do these protocols do?

They select one exact profile after the common identity, control, execution, and outcome contract, then keep planned versus actual conditions, deviations, delivery, viability, and downstream handoffs separate.

Supported delivery workflows

  • Common identity, execution, outcome & handoff
  • Suspension HEK293 · PEI-MAX · antibody plasmid
  • MDA-MB-231 · Lipofectamine 3000 · 24-well plasmid

Scope boundary

They do not recommend or auto-adjust cells, payloads, reagents, devices, formats, or scales beyond the two exact profiles, and exclude viral, in-vivo/LNP, germline, clinical/GMP execution, and universal success thresholds.

PRT-GD-COMMON-001Common identity, execution, outcome & handoff

Gene Delivery identity, source, control, execution, outcome, and typed-handoff foundation

Gene Delivery / Transfection · GD-FAMILY-CONTRACT-1.0

Official guidance reviewed
EXACT_SOURCE_PROFILE_REQUIREDMODEL_ROUTE_TOPOLOGY_PAYLOAD_LOCKNO_CROSS_PROFILE_NUMERIC_MIXINGSOURCE_SCALE_ONLY_UNLESS_EXPLICIT_ARITHMETICCONTROL_DISPOSITION_REQUIREDDELIVERY_VIABILITY_AND_OUTCOME_SEPARATETYPED_DOWNSTREAM_HANDOFFNO_UNIVERSAL_ACCEPTANCE_THRESHOLDRESEARCH_USE_ONLY

Match the cell, payload, and exact source profile first

Only two executable starters are available: suspension HEK293/PEI-MAX antibody DNA and MDA-MB-231/Lipofectamine 3000 in the exact 24-well path. Other cells, reagents, or formats are not auto-adjusted, and controls plus actual execution values must be recorded explicitly.

1

1. LOCK THE BIOLOGICAL MODEL AND PAYLOAD

Record the exact cell identity, source history, passage or adaptation state, topology, payload identity and downstream purpose before selecting a delivery profile.

2

2. SELECT ONE EXACT SOURCE PROFILE

Match route, model, topology, payload, reagent or device, kit or medium, vessel, scale, source revision and locator; any mismatch returns HOLD.

Condition: USER REQUIRED — one exact Gene Delivery profile ID or HOLD.
3

3. FREEZE THE SOURCE LEDGER

Preserve each source value separately from derived arithmetic, local qualification inputs and missing fields; never borrow a condition from another profile.

4

4. PREDECLARE READINESS AND CONTROLS

Record source-specific readiness and assign or explicitly omit every control with a reason before execution.

5

5. RECORD PREPARATION AND DELIVERY

Capture planned and actual component identities, amounts, units, order, timing, vessel, exposure and any deviation against the selected source profile.

Duration: SOURCE PROFILE REQUIRED
6

6. RECORD RECOVERY AND HANDOFF

Keep recovery conditions and the downstream Protein Production or CRISPR consumer receipt typed and versioned; do not duplicate the downstream recipe.

7

7. SEPARATE DELIVERY AND VIABILITY EVIDENCE

Record delivery readout and viability or morphology as separate observations with sample, control, replicate and time identities.

8

8. RECORD THE DOWNSTREAM BIOLOGICAL OUTCOME

Link expression, editing or another biological outcome without treating it as interchangeable with delivery success.

9

9. ISSUE A FAIL-CLOSED DISPOSITION

Assign READY, CONDITIONAL, REPEAT, REJECT, HOLD or SPECIALIST REVIEW with deviations, uncertainty, allowed claim and immutable evidence links.